INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
Direct Vent
Rear Vent
Model
BHDR36
DO NOT STORE
OR USE GASOLINE OR OTHER
FLAMMABLE VAPOURS AND LIQUIDS
IN THE VICINITY OF THIS OR ANY
OTHER APPLIANCE.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS:
* Do not try to light any appliance.
* Do not touch any electric switch.
Do not use any phone in your building.
* Extinguish all flames.
* Immediately call your gas supplier from
your neighbours phone. Follow the gas
suppliers instructions.
* If you cannot reach your gas supplier call the
fire department.
WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE,PERSONAL INJURY OR LOSS OF LIFE.
Installation Instructions & Homeowner's Manual
FOR YOUR SAFETY
* Installation and service must be performed
by a qualified installer, service agency or
your gas supplier.
475 Admiral Blvd., Mississauga
Ontario, Canada L5T 2N1
www.majesticproducts.com / www.vermontcastings.com
The Vermont Castings
Majestic Products Company
10001826
11/01 Rev. 1
Vue de la page 0
1 2 3 4 5 6 ... 35 36

Résumé du contenu

Page 1 - Rear Vent

- 1 -INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNERDirect VentRear VentModelBHDR36DO NOT STOREOR USE GASOLINE OR OTHERFLAMMABLE VAPOURS

Page 2 - TABLE OF CONTENTS

- 10 -Combustible Walls. Cut a 10-3/8"H x 9-3/8"W (265mmx 240mm) hole through the exterior wall and frame asshown. Fig. 14.Non-Combustible

Page 3 - INSTALLATION INSTRUCTIONS

- 11 -FINISHED WALL VENT TERMINATION(7DVRVT)Fig. 16 STEP 5Guide the vent termination 4" collar into the 4" pipe then the7" collar i

Page 4 - FIREPLACE DIMENSIONS

- 12 -VERTICAL SIDEWALL APPLICATIONSThe maximum number of 90 degree elbows per side wallinstallation is four (4), (includes 7DVRT90 off back of unit)T

Page 5 - FRAMING AND FINISHING

- 13 -SEE PAGE 15 FOR VENTINGREQUIREMENTS FOR SNORKELS.34567891011121314151617181920212223242526272829303 4 5 6 7 8 9 10 11 1

Page 6 - CERTIFIED TO

- 14 -X STEP 2Fig. 25. Measure wall thickness and cut adjustable zeroclearance sleeve parts to proper length (MAXIMUM 12").Adjust sleeve to mini

Page 7 - GAS LINE INSTALLATION

- 15 -BELOW GRADE INSTALLATIONSWhen it is not possible to meet the required vent termi-nal clearances of 12 inches (305mm) above grade levela model #7

Page 8 - GENERAL VENTING INFORMATION

- 16 -Fig. 36The minimum height of the vent above the highestpoint of penetration throught the roof is 2 feet. SeeFig. 36.TYPICAL STRAIGHT-UP INSTALL

Page 9 - Screw Holes

- 17 -CRIMPED END VENTING COMPONENTS7DVRVT - Through the wall Rear Vent TerminationStarter Kit -Model 7DVSK - Sidewall VentingStarter Kit - Model 7DVS

Page 10 - REAR VENTING APPLICATIONS

- 18 -GENERAL INFORMATION ON ASSEMBLINGTHE TWIST LOCK VENT PIPESWhen using CFM Majestic twist lock pipe it is not neces-sary to use silicone to seal t

Page 11 - (7DVRVT)

- 19 -Fig. 40Combustible Walls. Cut a 10-3/8"H x 9-3/8"W (265mmx 240mm) hole through the exterior wall and frame asshown. Fig. 40.Non-Comb

Page 12 - SIDE VIEW

- 2 -TABLE OF CONTENTSPLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE.Thank you and congratulations on your purchase.

Page 13 - Noncombustible Wall

- 20 -The maximum horizontal vent run is 20 feet (6100mm)when the vertical vent rise is 7.5 feet (2286mm). Fig. 43Fig. 43VERTICAL SIDEWALL INSTALLAT

Page 14 - ARE CONCENTRIC

- 21 -INSERTFig. 46The maximum number of elbow degrees in a system is270 o. (This does not include transition elbow from rearvent to vertical vent.) F

Page 15 - ROOF APPLICATIONS

- 22 -VENT SIDEWALL INSTALLATION*IMPORTANT* Minimum clearance between vent pipesand combustible materials is one (1") inch (25 mm) onbottom, sid

Page 16 - TYPICAL OFFSET INSTALLATION

- 23 -XSealing vent pipe andfirestop gaps with hightemperature sealant willrestrict cold air beingdrawn in around fireplace.Fig. 54 STEP 5(Fig. 54)

Page 17 - Model 7DVCS

- 24 -DO NOT BACK FILL AROUND SNORKEL.SOIL SHOULD NOT BE LESS THAN 4"BELOW SNORKEL.FOUNDATION RECESS SNORKEL SCREWSWALLSCREWSSHEET METALWATERTIGH

Page 18 - THE TWIST LOCK VENT PIPES

- 25 -1. Locate your fireplace.2. Plumb to centre of the (4") 90o transition elbow(7TDVRT90) from ceiling above and mark position.3. Cut openin

Page 19

- 26 -TWIST LOCK VENTING COMPONENTS7DVRVT - Through the wall Rear Vent TerminationStarter Kit -Model 7TDVSK - Sidewall VentingStarter Kit - Model 7TDV

Page 20 - 7TDVRT90

- 27 -GLASS FRAME REMOVAL1. Shut off gas.2. Let the fireplace cool if it has been operating.3. Remove top louvre. (See Louvre Removal)4. Open the lowe

Page 21 - (Dimensions in Feet)

- 28 -1 . Remove front glass. (See "Glass Removal" Section)2. Remove logs from the packaging.As with all plastics — these are not toys andsh

Page 22

- 29 -The burner and control system consists of:• burner tube • gas orifices• pilot assembly • thermopile• millivolt gas valveMost of these compo

Page 23 - INSTALLATION

- 3 -IMPORTANT:PLEASE REVIEW THE FOLLOWINGCAREFULLYRemove any plastic from trim parts before turningthe fireplace ON.It is normal for fireplaces fabri

Page 24

- 30 -4. Push in gas control knob slightlyand turn clockwise to"OFF". Do not force.5. Close control access panel.10. Push the control

Page 25 - Installation

- 31 -• GAS SUPPLY ON• SUPPLY LINE HOOKED UP• SHUTOFF VALVE OPENNONONONO• LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN.• FOR SPARK AT ELECTROD

Page 26 - TWIST LOCK VENTING COMPONENTS

- 32 -TROUBLE SHOOTING THE GAS CONTROL SYSTEMSIT 820 NOVA MILLIVOLT VALVESTART CHECKGLASS DOOR TO BE REMOVED BEFORE SERVICE WORKGAS SUPPLY ON• SHUTOF

Page 27 - OPERATING INSTRUCTIONS

- 33 -REPLACEMENT PARTS LISTDESCRIPTION BHDR361. Log Set Complete 100018181a. Log Front BH11b. Log Rear BH21c. Log Top Left BH31d. Log Top Right BH42.

Page 28 - FLAME ADJUSTMENT

- 34 -27262425224 a/b17161191513313233303029212319 a/b5 a/b34228363512LOHIPILOTADJPILOTONOFF7 a/b20 a/b188 a/b36 a/b10 1514#1 - COMPLETE LOG SET#1 - C

Page 29 - MAINTENANCE

- 35 -1. Slide fan assembly from the left side into fireplaceopening, line up mounting holes with screw studs onback of fireplace and fasten with #10-

Page 30 - LIGHTING INSTRUCTIONS

- 36 -OPTIONAL CERAMIC REFRACTORYINSTALLATION6. Hang Bay Window Frame assembly over existing glassframe.Do not remove existing glass frame7. Re-instal

Page 31 - HONEYWELL MILLIVOLT VALVE

- 4 -A 36" 914mmB 34 1/4"870mmC 21" 533mmD 33" 838mmE 24" 610mmF 16" 406mmG 19" 483mmH 23 7/8"606mmI 27 1/2&qu

Page 32 - SIT 820 NOVA MILLIVOLT VALVE

- 5 -Ref. Mantel Ref. Mantel From Mantel Leg fromDepth Top Louvre Fireplace SideV 10" (254 mm) A 12" (305 mm) 10" (254mm)W 8" (

Page 33 - ESCRIPTION BHDR36

- 6 -Do not use this fireplace if any part of it hasbeen under water. Immediately call a qualifiedservice technician to inspect the fireplaceand repl

Page 34 - REPLACEMENT PARTS

- 7 -PILOTTPTHTPTHSIT VALVE1/2" GAS SUPPLY1/2" X 3/8" REDUCER3/8" NIPPLE3/8" NIPPLE3/8" NIPPLE3/8" X 3/8" SHUT

Page 35 - OUTSIDE VIEW

- 8 -VVVVVVVVVXXXDEBBBCBMBAJKAFLGGTERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA(TERMINATION PROHIBITED)HIFixedClosedFixedClosedOpenableOp

Page 36 - OPTIONAL REMOTE CONTROL

- 9 -Fig. 11Outside CornerInside CornerTermination ClearancesTermination clearances for buildings with combustible and noncombustible exteriors. A =Co

Commentaires sur ces manuels