- 1 -INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNERDirect VentRear VentModelBHDR36DO NOT STOREOR USE GASOLINE OR OTHERFLAMMABLE VAPOURS
- 10 -Combustible Walls. Cut a 10-3/8"H x 9-3/8"W (265mmx 240mm) hole through the exterior wall and frame asshown. Fig. 14.Non-Combustible
- 11 -FINISHED WALL VENT TERMINATION(7DVRVT)Fig. 16 STEP 5Guide the vent termination 4" collar into the 4" pipe then the7" collar i
- 12 -VERTICAL SIDEWALL APPLICATIONSThe maximum number of 90 degree elbows per side wallinstallation is four (4), (includes 7DVRT90 off back of unit)T
- 13 -SEE PAGE 15 FOR VENTINGREQUIREMENTS FOR SNORKELS.34567891011121314151617181920212223242526272829303 4 5 6 7 8 9 10 11 1
- 14 -X STEP 2Fig. 25. Measure wall thickness and cut adjustable zeroclearance sleeve parts to proper length (MAXIMUM 12").Adjust sleeve to mini
- 15 -BELOW GRADE INSTALLATIONSWhen it is not possible to meet the required vent termi-nal clearances of 12 inches (305mm) above grade levela model #7
- 16 -Fig. 36The minimum height of the vent above the highestpoint of penetration throught the roof is 2 feet. SeeFig. 36.TYPICAL STRAIGHT-UP INSTALL
- 17 -CRIMPED END VENTING COMPONENTS7DVRVT - Through the wall Rear Vent TerminationStarter Kit -Model 7DVSK - Sidewall VentingStarter Kit - Model 7DVS
- 18 -GENERAL INFORMATION ON ASSEMBLINGTHE TWIST LOCK VENT PIPESWhen using CFM Majestic twist lock pipe it is not neces-sary to use silicone to seal t
- 19 -Fig. 40Combustible Walls. Cut a 10-3/8"H x 9-3/8"W (265mmx 240mm) hole through the exterior wall and frame asshown. Fig. 40.Non-Comb
- 2 -TABLE OF CONTENTSPLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE.Thank you and congratulations on your purchase.
- 20 -The maximum horizontal vent run is 20 feet (6100mm)when the vertical vent rise is 7.5 feet (2286mm). Fig. 43Fig. 43VERTICAL SIDEWALL INSTALLAT
- 21 -INSERTFig. 46The maximum number of elbow degrees in a system is270 o. (This does not include transition elbow from rearvent to vertical vent.) F
- 22 -VENT SIDEWALL INSTALLATION*IMPORTANT* Minimum clearance between vent pipesand combustible materials is one (1") inch (25 mm) onbottom, sid
- 23 -XSealing vent pipe andfirestop gaps with hightemperature sealant willrestrict cold air beingdrawn in around fireplace.Fig. 54 STEP 5(Fig. 54)
- 24 -DO NOT BACK FILL AROUND SNORKEL.SOIL SHOULD NOT BE LESS THAN 4"BELOW SNORKEL.FOUNDATION RECESS SNORKEL SCREWSWALLSCREWSSHEET METALWATERTIGH
- 25 -1. Locate your fireplace.2. Plumb to centre of the (4") 90o transition elbow(7TDVRT90) from ceiling above and mark position.3. Cut openin
- 26 -TWIST LOCK VENTING COMPONENTS7DVRVT - Through the wall Rear Vent TerminationStarter Kit -Model 7TDVSK - Sidewall VentingStarter Kit - Model 7TDV
- 27 -GLASS FRAME REMOVAL1. Shut off gas.2. Let the fireplace cool if it has been operating.3. Remove top louvre. (See Louvre Removal)4. Open the lowe
- 28 -1 . Remove front glass. (See "Glass Removal" Section)2. Remove logs from the packaging.As with all plastics — these are not toys andsh
- 29 -The burner and control system consists of:• burner tube • gas orifices• pilot assembly • thermopile• millivolt gas valveMost of these compo
- 3 -IMPORTANT:PLEASE REVIEW THE FOLLOWINGCAREFULLYRemove any plastic from trim parts before turningthe fireplace ON.It is normal for fireplaces fabri
- 30 -4. Push in gas control knob slightlyand turn clockwise to"OFF". Do not force.5. Close control access panel.10. Push the control
- 31 -• GAS SUPPLY ON• SUPPLY LINE HOOKED UP• SHUTOFF VALVE OPENNONONONO• LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN.• FOR SPARK AT ELECTROD
- 32 -TROUBLE SHOOTING THE GAS CONTROL SYSTEMSIT 820 NOVA MILLIVOLT VALVESTART CHECKGLASS DOOR TO BE REMOVED BEFORE SERVICE WORKGAS SUPPLY ON• SHUTOF
- 33 -REPLACEMENT PARTS LISTDESCRIPTION BHDR361. Log Set Complete 100018181a. Log Front BH11b. Log Rear BH21c. Log Top Left BH31d. Log Top Right BH42.
- 34 -27262425224 a/b17161191513313233303029212319 a/b5 a/b34228363512LOHIPILOTADJPILOTONOFF7 a/b20 a/b188 a/b36 a/b10 1514#1 - COMPLETE LOG SET#1 - C
- 35 -1. Slide fan assembly from the left side into fireplaceopening, line up mounting holes with screw studs onback of fireplace and fasten with #10-
- 36 -OPTIONAL CERAMIC REFRACTORYINSTALLATION6. Hang Bay Window Frame assembly over existing glassframe.Do not remove existing glass frame7. Re-instal
- 4 -A 36" 914mmB 34 1/4"870mmC 21" 533mmD 33" 838mmE 24" 610mmF 16" 406mmG 19" 483mmH 23 7/8"606mmI 27 1/2&qu
- 5 -Ref. Mantel Ref. Mantel From Mantel Leg fromDepth Top Louvre Fireplace SideV 10" (254 mm) A 12" (305 mm) 10" (254mm)W 8" (
- 6 -Do not use this fireplace if any part of it hasbeen under water. Immediately call a qualifiedservice technician to inspect the fireplaceand repl
- 7 -PILOTTPTHTPTHSIT VALVE1/2" GAS SUPPLY1/2" X 3/8" REDUCER3/8" NIPPLE3/8" NIPPLE3/8" NIPPLE3/8" X 3/8" SHUT
- 8 -VVVVVVVVVXXXDEBBBCBMBAJKAFLGGTERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA(TERMINATION PROHIBITED)HIFixedClosedFixedClosedOpenableOp
- 9 -Fig. 11Outside CornerInside CornerTermination ClearancesTermination clearances for buildings with combustible and noncombustible exteriors. A =Co