INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
10002734
6/00 Rev. 0
DO NOT STORE
OR USE GASOLINE OR OTHER
FLAMMABLE VAPOURS AND LIQUIDS
IN THE VICINITY OF THIS OR ANY
OTHER APPLIANCE.
FOR YOUR SAFETY
WHAT TO DO IF YOU SMELL GAS:
* Do not try to light any appliance.
* Do not touch any electric switch
* Do not use any phone in your building.
* Immediately call your gas supplier from
your neighbours phone. Follow the gas
suppliers instructions.
* If you cannot reach your gas supplier call
the fire department.
WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
* INSTALLATION AND SERVICE MUST BE
PERFORMED BY A QUALIFIED INSTALLER,
SERVICE AGENCY OR YOUR GAS SUPPLIER.
Free-Standing
Fireplaces
MODEL A232
Installation Instructions & Homeowner's Manual
Vue de la page 0
1 2 3 4 5 6 ... 17 18

Résumé du contenu

Page 1 - Fireplaces

INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER 100027346/00 Rev. 0DO NOT STOREOR USE GASOLINE OR OTHERFLAMMABLE VAPOURS AND LIQUIDSIN TH

Page 2 - TABLE OF CONTENTS

- 10 -KR2KR5KR6KR4KR3KR1Burner Lava Rock PlacementGLASS CLEANINGIt will be necessary to clean the glass periodically.During start-up condensation, whi

Page 3 - INSTALLATION INSTRUCTIONS

- 11 -Fig. 20aFLAME ADJUSTMENT (RN/RP MODELS)For units equipped with Hi/Lo valves, flame adjustmentis accomplished by rotating the Hi/Lo adjustment kn

Page 4 - FIREPLACE DIMENSIONS

- 12 -4. Push in gas control knob slightlyand turn clockwise to"OFF". Do not force.5. Close control access panel.10. Push the control

Page 5 - PREPARATION

- 13 -TROUBLE SHOOTING THE GAS CONTROL SYSTEMSIT NOVA 820 MILLIVOLT VALVENote: Before trouble shooting the gas control system, be sure external gas

Page 6 - OPTIONAL FAN KIT - FK24

- 14 -• GAS SUPPLY ON• SUPPLY LINE HOOKED UP• SHUTOFF VALVE OPENNONONONO• LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN.• FOR SPARK AT ELECTROD

Page 7 - VENTING OF THE A232 FIREPLACE

- 15 -REPLACEMENT PARTS LISTDESCRIPTION A2321. Log Set Complete 100001601a. Log Ember Front KR11b. Log Front Left KR21c. Log Front Right KR31d. Log Re

Page 8 - VENT SAFETY SYSTEM

- 16 -2930275/6a/b191813111715287a/b21a,b44414243313236 a/b 3739464539434142itHILOOFFPILOT25a/b4847404014334243334926#1 - COMPLETE LOG SET -- A2321b1

Page 9 - OPERATING INSTRUCTIONS

- 17 -OPTIONSMRC1 - On/Off Button Remote ControlMRC2 - Temperature Control RemoteMRC3 - Temperature Control w/digital display &24 hour programmabl

Page 10 - CLEANING PROCEDURE

- 18 -410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7885 www.vermontcastings.comCFM Majestic, Inc.© CopyrightCFM Majestic, Inc.10

Page 11 - FLAME CHARACTERISTICS

- 2 -TABLE OF CONTENTSPLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE.IMPORTANT: Read all instructions and warnings

Page 12

- 3 -This gas fireplace should be installed by a qualified installer inaccordance with local building codes and with current CAN /CGA-B149 (. 1 or .2)

Page 13 - SIT NOVA 820 MILLIVOLT VALVE

- 4 -ABCDEFGHJIKFIREPLACE DIMENSIONSMODEL A232A 25" 635mmB 24 1/8"613mmC 16" 406mmD 20" 508mmE 19" 483mmF 21" 533mmG 31

Page 14 - HONEYWELL MILLIVOLT VALVE

- 5 -GAS INLET & MANIFOLD PRESSURESInput MinimumInput MaximumManifold PressureNATURALLP (Propane)11" wc13" wc10" wc4.5" wc7&qu

Page 15 - REPLACEMENT PARTS LIST

- 6 -INSTALLATION OF REMOTESWITCH FOR RN/RP GAS VALVEInstall on/off switch assembly on either the rear right orleft side of the A232 Gas Fireplace.1.

Page 16 - REPLACEMENT PARTS

- 7 -Fig. 14STRAIGHT BVENT CHIMNEYCOMMON FLUE INSTALLATIONSIn some areas it is possible to vent more than one gasfireplace into the same flue. You mu

Page 17

- 8 -CheckDraftHereFig. 16Retrofitting To An Existing Brick ChimneyIt is strongly recommends installing an approved chimneyliner in an existing brick

Page 18 - For Gas Appliance Products*

- 9 -GENERAL GLASS INFORMATIONOnly glass approved for use in theseproducts may be used for replacement.1. The use of substitute glass will void all pr

Commentaires sur ces manuels

Pas de commentaire